Hi amir,
That kind of lining should not have failed. Can you tell me operation conditions like temperature and pressure, etc. as well as how long the valve has ben in operation?
Thanks,
Matthias
------------------------------
Matthias Walschburger
Operations Director Latin America
Koch Industries, Inc.
Canton OH
+1 330 488 1651
------------------------------
Original Message:
Sent: 07-14-2020 04:08 AM
From: AAMIR SADDIQ
Subject: Y-TYPE rubber lined Glove valve Failure in 32% HCL service.
As per Valve Technical Data sheet, the rubber lining material is VULCOFERRAN /CSM/BORNUMHARZ BH 6101
------------------------------
AAMIR SADDIQ
STATIONARY ENGINEER
SABIC
JUBAIL
00966133574273
Original Message:
Sent: 07-13-2020 08:30 AM
From: Matthias Walschburger
Subject: Y-TYPE rubber lined Glove valve Failure in 32% HCL service.
What kind of rubber was used?
------------------------------
Matthias Walschburger
Operations Director Latin America
Koch Industries, Inc.
Canton OH
+1 330 488 1651
Original Message:
Sent: 07-12-2020 05:29 AM
From: AAMIR SADDIQ
Subject: Y-TYPE rubber lined Glove valve Failure in 32% HCL service.
Does anyone have experience such rubber line failure,
----------
It is operated in 32% Hcl service
------------------------------
AAMIR SADDIQ
STATIONARY ENGINEER
SABIC
JUBAIL
00966133574273
------------------------------