Cant really help with any referrals, though I can say tha ton our assets, the lap joints suffer way more issues than weld neck ...
Team: I could use a referral to any previous MTI threads or industry publications (i.e. PVP papers) related to failure modes ...
Jesse - as others have said it is wise to test to flange pressure test limit. An important rationale is that now you have to track ...
Hi Jesse, You would want to test the new piping at the recommended 1.5 x 285 psi. You should either remove the PSV, if possible, ...
Hello all Lets call - P d The design pressure (internal pressure) - S t The allowable stress of the ...